Skip to product information
1 of 2

AEA Ribbon Mics | AEA1029C0001

AEA 1029

AEA 1029

Regular price €1.899,00
Regular price Sale price €1.899,00
Sale Sold out
Taxes included.
Custom ordered for you: Inquire for a delivery timeframe.
Quantity

AEA 1029

The AEA 1029 is our Ultra-Clean Stereo VCA Compressor featuring a proprietary discrete op-amp design in a half-rack chassis

1029 Overview

  • Half-rack form factor
  • 2 channels of XLR in and out
  • 3 position Peak Fast, RMS, and Peak Slow sensing times
  • Variable threshold from -20dBu to 20dBu
  • Up to 20dB of makeup gain
  • Dry/Wet percentage control knob
  • True bypass relay switching
  • Circuit, including discrete op-amp, designed by Fred Forssell
  • Made in the U.S.A.
View full details
>>

Product Description

Smooth Compression, Perfect Clarity

From subtle smoothing to brickwall limiting, the AEA 1029 provides ultra-clean compression that you have to hear to believe.

  • The AEA 1029 utilizes a proprietary discrete op-amp design by Fred Forssell and two THAT 4305 VCA chips run off of a single RMS detector being fed by the summed input signals. This design results in a versatile compressor with a clear and balanced sound perfect for taming vocals or smashing drum overheads. Designed to pair well with our TRP and RPQ series preamps, the 1029 Stereo VCA compressor is perfect for recording and/or mixing stereo microphones.
  • Packed into a sleek, half-rack design – the AEA 1029 is perfect for desktop use or for those looking to save space in their rack. But don’t let its size fool you, the 1029 is a full-featured compressor that packs a punch. With 3 position Sensing Time (Peak Fast, Slow, and RMS) and a variable ratio from 1:1 – Limit, the 1029 can go from subtle to extreme as you see fit. Equally at home in a bedroom or professional studio, the AEA 1029 is the perfect addition to any engineer’s toolkit.
>>

Features & Specs

AEA 1029 Specifications

Input Impedance: 10 kΩ Actively Balanced
Max Input Level:
+26 dBu
Input CMRR:
Better than 70dB (22Hz to 22kHz)
Output Stage:
50 Ω Active Balanced Floating
Max Output Level:
+26 dBu Balanced Load, +22 dBu Unbalanced Load
Minimum Load Impedance:
600 Ω

Signal-to-Noise Ratio:
Dry: -97dBu, Wet: -91dBu

Frequency Response
Dry:
10 Hz to 200 kHz (+0 dB, -0.05 dB)
Wet:
10 Hz to 200 kHz (+0 dB, -0.1 dB)
Input and Output XLR Polarity:
Pin 2 +, Pin 3 -
Absolute Phase: Non-inverting

Attack and Release Times
Peak Fast:
4ms attack, 17ms release
RMS:
12ms attack, 50ms release
Peak Slow: 4ms attack, 200ms release

LED Signal Level Indicators
7 Segment LED Meters:
-20, -12, -4, 0, 6, 10, 20 (6dB before clipping)

Gain Reduction Indicator
6 Segment LED Meter:
-1, -2, -3, -6, -9, -12dB gain reduction

Power Consumption:
6 Watts
Line Voltage:
100 to 240 VAC

Dimensions:
Half-rack wide (8.5 in), 1 rack unit high (1.8 in) 8 in deep (measured with knobs) (21.59 cm x 20.32 cm x 4.6 cm)
Weight: 2
lb 6oz (~0.9 kg)
Power Supply Weight: 1 lbs 1 oz (~0.5 kg)
Power Supply Length:
7 feet 8.5 inches (2.3 m), Power supply lengthmay be supplemented with longer IEC cable.

In compliance with the following requirements: RoHS2 Directive: 2011/65/EU

Media

> > >

Documents

GPSR Information

Manufacturer Information

Audio Engineering Associates
1029 N. Allen Ave., Pasadena, CA 91104, USA

Importer Information

Klemm Music Technology e.K.
Sebastian-Kneipp-Str. 96, 37217 Ziegenhagen, Deutschland

Warnings & Safety Information

  • Risk of electric shock – Never open the device while it is connected to the power supply, as high – potentially life-threatening – mains voltages are present inside. Leave maintenance work exclusively to qualified specialist personnel.
  • Water and Moisture - Do not use the unit near any source of water or in excessively moist
    environments.
  • Object and Liquid Entry - Care should be taken so that objects do not fall, and liquids are not spilled, into the enclosure through openings.
  • Ventilation - When installing the unit in a rack or any other location, be sure there is adequate
    ventilation. Improper ventilation will cause overheating and can damage the unit.
  • Heat - The unit should be situated away from heat sources, or other equipment that produce heat.
  • Power Sources - The unit should be connected to a power supply only of the type described in the
    operating instructions, or as marked on the unit.
  • Power Cord Protection - AC power supply cords should be routed so that they are not likely to be
    walked on or pinched by items placed upon or against them. Pay particular attention to cords at
    plugs, convenience receptacles, and the point where they exit from the unit. Never take hold of the
    plug or cord if your hand is wet. Always grasp the plug body when connecting or disconnecting it.
  • Non-use Periods - The AC power supply cord of the unit should be unplugged from the AC outlet when left unused for a long period of time.
  • Damage requiring maintenance – In such cases, please contact a qualified technician.