Passer aux informations produits
1 de 6

AudioScape Engineering Co. | GS-CL20

MAP CL-20 [500-Series] Compressor

MAP CL-20 [500-Series] Compressor

Prix habituel €699,00
Prix habituel Prix promotionnel €699,00
Promotion Épuisé
Taxes incluses.
Précommandez maintenant ; en raison d'une forte demande, l'expédition vers l'Europe est prévue sous 6 à 10 semaines après l'achat.
Quantité

Instant mojo and mid-century vibe to any track

 

Introducing the MAP CL-20 Compressor/ Limiter, AudioScape's recreation of the original Melcor® CL-20 FET unit released in the late 1960’s. The CL-20, along with Melcor’s® GME-20 EQ, could often be found installed in RCA’s custom built consoles from the late 60’s/ early 70’s. A big part of the CL-20’s distinctive box tone is the 1731® discrete op-amps used. Originally designed by Melcor®, the 1731® preceded another famous Farmingdale, Long Island audio-maker’s well-known discrete op amp. AudioScape now make these lovely 1731® op amps at their factory in Florida, and the CL-20 utilizes no less than three of these discrete beauties in its circuit topology. The MAP CL-20 has been adapted to a 500 Series format.

 

**HASSLE-FREE 2-YEAR WARRANTY INCLUDED!

Afficher tous les détails
>>

Description du produit

The CL-20 appears deceptively simple at first blush, there’s only two controls, one for setting threshold and the other for setting make-up gain, and a meter monitoring gain reduction, but there’s quite a lot going on. The amount and the ballistics of the compression are set by the threshold level. Changes in the threshold level automatically adjust the attack and release times, simultaneously. The higher the threshold, the more subtle the compression. At lower threshold settings, the CL-20 is quite aggressive, like an 1176. Fast attack and fast release times. When adjusted to higher settings (past the 12 o’clock point), release times will slow down, however, for a much smoother, more transparent compression.

The CL-20 , like all the MAP 1731-based products, will add instant mojo and mid-century vibe to any track it’s applied to.

AudioScape is manufacturing MAP products again, bringing that classic mid-century vibe to the new millennium. In the early 70’s, MAP had descended from Melcor® Industries. When Melcor® abandoned the audio business for calculators around 1970, a group of their engineers carried on as Modular Audio Products, with the 1731® op amp at the heart of a range of products. Of course, these early discrete op amp beauties are highly sought after today. The CL-20 Compressor/Limiter joins the D.AM-27 Dual Mic Preamp in AudioScape's MAP lineup.

>>

Caractéristiques et spécifications

FEATURES & SPECS:

  • VINTAGE STYLE FET COMPRESSION AT ITS FINEST
  • VINTAGE MELCOR/MAP MODULAR CONSOLE FORMAT ADAPTED FOR 500 SERIES
  • 3 QTY 1731 DISCRETE MAP OPAMPS, ALL THROUGH HOLE CONSTRUCTION LIKE THE ORIGINALS
  • CL CONTROL, ONE CONTROL TO RULE THEM ALL, TAKES THE COMPRESSION BEHAVIOUR FROM AGGRESSIVE TO TRANSPARENT, EXACTLY LIKE THE ORIGINAL
  • OUTPUT CONTROL, ADDS THE PROPER AMOUNT OF MAKEUP GAIN NEEDED AFTER COMPRESSION IS APPLIED
  • BYPASS SWITCH, USED TO BYPASS THE ORIGINAL CIRCUIT, AND IS TRUE BYPASS
  • 24MM ALPHA POTENTIOMETERS
  • PERIOD CORRECT CARBON COMPOSITION RESISTORS IN THE AUDIO PATH ALONG WITH THE CORRECT POLY FILM CAPACITORS, ALL WHERE THEY BELONG
> > >

Documents

DOCUMENTATION:

Informations GPSR

Informations sur le fabricant

AudioScape Engineering Co.
1631 S Nova Road, South Daytona, FL 32119, United States of America

Informations sur l'importateur

von Brönner GmbH
Franziusstr. 12, 60314 Frankfurt/Main, Germany

Avertissements et informations sur la sécurité

  • Eau et humidité - N'utilisez pas l'appareil à proximité d'une source d'eau ou dans des environnements excessivement humides.
  • Introduction d'objets et de liquides - Il convient de veiller à ce qu'aucun objet ne tombe directement sur le module de la série 500 et qu'aucun liquide ne soit renversé dans le boîtier par ses ouvertures.
  • Ventilation - Lors de l'installation de l'appareil dans un rack ou à tout autre endroit, assurez-vous que la ventilation est adéquate. Une ventilation inadéquate entraînera une surchauffe et pourra endommager l'appareil.
  • Chaleur - L'appareil doit être situé à l'écart des sources de chaleur ou de tout autre équipement produisant de la chaleur.
  • Sources d'alimentation - Le module de la série 500 fonctionnera avec n'importe quel châssis standard approuvé de la série 500 ; cependant, nous vous recommandons d'en acheter un de haute qualité avec suffisamment de puissance pour alimenter toutes vos unités, permettant 500 milliampères d'une alimentation stable de ±16 volts.
  • Protection du cordon d'alimentation - Assurez-vous toujours que le module de la série 500 est fermement inséré dans le connecteur du châssis avant de le visser sur le panneau avant.
  • Périodes de non-utilisation - Le cordon d'alimentation CA de l'unité doit être débranché de votre châssis de la série 500 lorsqu'il n'est pas utilisé pendant une période prolongée.
  • Dommages nécessitant une intervention - Veuillez vous adresser à un technicien qualifié.