Ir directamente a la información del producto
1 de 2

AEA Ribbon Mics | AEA1029C0001

AEA 1029

AEA 1029

Precio habitual €1.899,00
Precio habitual Precio de oferta €1.899,00
Oferta Agotado
Impuestos incluidos.
Custom ordered for you: Inquire for a delivery timeframe.
Cantidad

AEA 1029

The AEA 1029 is our Ultra-Clean Stereo VCA Compressor featuring a proprietary discrete op-amp design in a half-rack chassis

1029 Overview

  • Half-rack form factor
  • 2 channels of XLR in and out
  • 3 position Peak Fast, RMS, and Peak Slow sensing times
  • Variable threshold from -20dBu to 20dBu
  • Up to 20dB of makeup gain
  • Dry/Wet percentage control knob
  • True bypass relay switching
  • Circuit, including discrete op-amp, designed by Fred Forssell
  • Made in the U.S.A.
Ver todos los detalles
>>

Descripción del producto

Smooth Compression, Perfect Clarity

From subtle smoothing to brickwall limiting, the AEA 1029 provides ultra-clean compression that you have to hear to believe.

  • The AEA 1029 utilizes a proprietary discrete op-amp design by Fred Forssell and two THAT 4305 VCA chips run off of a single RMS detector being fed by the summed input signals. This design results in a versatile compressor with a clear and balanced sound perfect for taming vocals or smashing drum overheads. Designed to pair well with our TRP and RPQ series preamps, the 1029 Stereo VCA compressor is perfect for recording and/or mixing stereo microphones.
  • Packed into a sleek, half-rack design – the AEA 1029 is perfect for desktop use or for those looking to save space in their rack. But don’t let its size fool you, the 1029 is a full-featured compressor that packs a punch. With 3 position Sensing Time (Peak Fast, Slow, and RMS) and a variable ratio from 1:1 – Limit, the 1029 can go from subtle to extreme as you see fit. Equally at home in a bedroom or professional studio, the AEA 1029 is the perfect addition to any engineer’s toolkit.
>>

Características y especificaciones

AEA 1029 Specifications

Input Impedance: 10 kΩ Actively Balanced
Max Input Level:
+26 dBu
Input CMRR:
Better than 70dB (22Hz to 22kHz)
Output Stage:
50 Ω Active Balanced Floating
Max Output Level:
+26 dBu Balanced Load, +22 dBu Unbalanced Load
Minimum Load Impedance:
600 Ω

Signal-to-Noise Ratio:
Dry: -97dBu, Wet: -91dBu

Frequency Response
Dry:
10 Hz to 200 kHz (+0 dB, -0.05 dB)
Wet:
10 Hz to 200 kHz (+0 dB, -0.1 dB)
Input and Output XLR Polarity:
Pin 2 +, Pin 3 -
Absolute Phase: Non-inverting

Attack and Release Times
Peak Fast:
4ms attack, 17ms release
RMS:
12ms attack, 50ms release
Peak Slow: 4ms attack, 200ms release

LED Signal Level Indicators
7 Segment LED Meters:
-20, -12, -4, 0, 6, 10, 20 (6dB before clipping)

Gain Reduction Indicator
6 Segment LED Meter:
-1, -2, -3, -6, -9, -12dB gain reduction

Power Consumption:
6 Watts
Line Voltage:
100 to 240 VAC

Dimensions:
Half-rack wide (8.5 in), 1 rack unit high (1.8 in) 8 in deep (measured with knobs) (21.59 cm x 20.32 cm x 4.6 cm)
Weight: 2
lb 6oz (~0.9 kg)
Power Supply Weight: 1 lbs 1 oz (~0.5 kg)
Power Supply Length:
7 feet 8.5 inches (2.3 m), Power supply lengthmay be supplemented with longer IEC cable.

In compliance with the following requirements: RoHS2 Directive: 2011/65/EU

Media

> > >

Documentos

Información GPSR

Información del fabricante

Audio Engineering Associates
1029 N. Allen Ave., Pasadena, CA 91104, USA

Información del importador

Klemm Music Technology e.K.
Sebastian-Kneipp-Str. 96, 37217 Ziegenhagen, Deutschland

Advertencias e información de seguridad

  • Riesgo de descarga eléctrica – No abra nunca el dispositivo mientras esté conectado a la red eléctrica, ya que en su interior existen tensiones de red elevadas que pueden poner en peligro la vida. Deje los trabajos de mantenimiento exclusivamente en manos de personal especializado cualificado.
  • Agua y humedad - No utilice la unidad cerca de ninguna fuente de agua ni en entornos excesivamente húmedos.
  • Entrada de objetos y líquidos - Debe tenerse cuidado de que no caigan objetos ni se derramen líquidos en el interior de la carcasa a través de las aberturas.
  • Ventilación - Al instalar la unidad en un rack o en cualquier otra ubicación, asegúrese de que haya una ventilación adecuada. Una ventilación inadecuada provocará un sobrecalentamiento y puede dañar la unidad.
  • Calor - La unidad debe situarse lejos de fuentes de calor u otros equipos que produzcan calor.
  • Fuentes de alimentación - La unidad debe conectarse únicamente a una fuente de alimentación del tipo descrito en las instrucciones de funcionamiento o según se indique en la unidad.
  • Protección del cable de alimentación - Los cables de alimentación de CA deben colocarse de modo que no sea probable que se pisen o sean aplastados por objetos colocados sobre ellos o contra ellos. Preste especial atención a los cables en los enchufes, las bases de conexión y el punto por donde salen de la unidad. No sujete nunca el enchufe ni el cable si tiene las manos mojadas. Sujete siempre el cuerpo del enchufe al conectarlo o desconectarlo.
  • Periodos sin uso - El cable de alimentación de CA de la unidad debe desenchufarse de la toma de CA cuando no se utilice durante un largo periodo de tiempo.
  • Daños que requieren mantenimiento – En tales casos, póngase en contacto con un técnico cualificado.